1, clean the reverse osmosis membrane element in the reverse osmosis system;
2, use the reverse osmosis equipment water configuration into sterilization liquid, with sterilization liquid cleaning the entire reverse osmosis system.
3, use the germicidal solution to clean the reverse osmosis system, so that it fills the entire equipment, and then close the entire system pipeline valve, so that the germicidal solution stays in the reverse osmosis system.
4. If the system temperature is below 27°C, the system should be cleaned and filled again every 30 days with a new germicidal solution. Reverse osmosis system temperature if higher than 27 ℃, sterilization protection fluid can not exceed 15 days, the replacement cycle must be less than 15 days once.
5, if it is to be put into use again, first low-pressure flushing 1h, then high-pressure flushing 5-10min, flushing, open the system of all the water production valve. In the official put into use before, reverse osmosis equipment in the sterilization liquid must be completely flushed clean.