Home ProductsNews&DrawingsContact Us
Home > Products > Winder® FRP MEMBRANE HOUSINGS > 8" FRP MEMBRANE HOUSINGS-2019DESIGN
W80S300/450 FRP MEMBRANE HOUSINGS
W80S300/450 FRP MEMBRANE HOUSINGS frp membrane housingW80S300/450 FRP MEMBRANE HOUSINGS W80S300/450 FRP MEMBRANE HOUSINGS frp membrane housings

W80S300/450 FRP MEMBRANE HOUSINGS

Winder frp membrane housings-2019 design


Hydrostatic Water Leakage Test-1.4 Times of Operation Pressure

   

Low pressure frp membrane housing-Winder series with similar structure

Available in 150,300.450 psi pressure rating

Accommodates standard make 8" Membrane Element

Element length: 40" x (1-8)

Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.

Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF


Drawings:

2020 DRAWING WINDER W80S450 FRP MEMBRANE HOUSING-HBCDHM.pdf

2020 DRAWING WINDER W80S300 FRP MEMBRANE HOUSING-HBCDHM.pdf


Inquire Now
Share:
Download
W80S300/450 FRP MEMBRANE HOUSINGS frp membrane housingW80S300/450 FRP MEMBRANE HOUSINGS W80S300/450 FRP MEMBRANE HOUSINGS frp membrane housings

Winder frp membrane housing pressure vessels

Low pressure frp membrane housing-Winder series with similar structure

Available in 150,300.450 psi pressure rating


Hydrostatic Water Leakage Test-1.4times of operation pressure

Model:W80S1000-5(3" side port×4 ports)

   

Side Entry Design

Available in 300 psi pressure rating

Accommodates standard make 8" Membrane Element

Element length: 40" x (1-8)

Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.

Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF


Key Features:

Operating Temp Range: -10°C ---49°C

Internal permeate port not to exceed 125PSI(0.88MPa)

Operating pH Range: 3 – 11

Cleaning pH Range: 2 – 12 (less than 30 minutes)

Mirror inner wall and brightly surface.

Multi-ports option

White color is as standard. Customized colors are also available.

ASME Code stamp available upon request


Differences of mebrane housings Winder 2012,2019, Rohone aluminium cap and ABS cap design:

W80S300 FRP MEMBRANE HOUSINGS


Quality Assurance

Hydro-static Leakage Test Pressure:

Standard:

100% test, not sampling

— 100,000 times cycle test

— Burst test with 6 times of its operating pressure

— 100% QA test with 1.5x design hydraulic pressure.

ASME: 1.1x Design Pressure

— 100% QA inspection and cleaning before final

packaging and delivery to customers.

— Submitted for NSF standard 61


Winder frp membrane housings shell body thickness: approx 6mm to ensure to withstand burst pressure 6 times of operation pressure:

W80S300 FRP MEMBRANE HOUSINGS


Applications:

Winder FRP membrane housing pressure vessels are widely used for industrial waste water treatment, seawater desalination, brackish water desalination, RO system for electronics, electric power, food & beverage, metallurgy, chemical, pharmaceutical and other fields.


Notice:

Please operate in accordance with User Guide!

All information is subject to change without prior notice. Please contact us for the latest product information and specifications.