Home ProductsNews&DrawingsContact Us
Home > Products > FRP Membrane Housing Pressure Vessels > 4 INCH END ENTRY > 300PSI
FRP MEMBRANE HOUSINGS W40E300
FRP MEMBRANE HOUSINGS W40E300FRP MEMBRANE HOUSINGS W40E300FRP MEMBRANE HOUSINGS W40E300FRP MEMBRANE HOUSINGS W40E300FRP MEMBRANE HOUSINGS W40E300

W40E300 FRP MEMBRANE HOUSINGS

Winder® frp membrane housing pressure vessels

4" End Entry Design

Available in 300 psi, 450Psi, 600Psi, 1000Psi, 1200Psi pressure rating

Accommodates standard make 4" Membrane Element (4040,4080,40120,40160)

Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.

Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF


Drawing:

220913 Drawing of W40E300-Winder FRP RO membrane housings -Chengda water.pdf



Catalog of Winder frp membrane housings:

200625 catalog - Winder ASME coded FRP membrane housing-HBCDHM.pdf


Inquire Now
Share:
Download
FRP MEMBRANE HOUSINGS W40E300FRP MEMBRANE HOUSINGS W40E300FRP MEMBRANE HOUSINGS W40E300FRP MEMBRANE HOUSINGS W40E300FRP MEMBRANE HOUSINGS W40E300

Winder® frp membrane housing pressure vessels


4" End Entry Design

Available in 300 psi, 450Psi, 600Psi, 1000Psi, 1200Psi pressure rating

Accommodates standard make 4" Membrane Element(4040,4080,40120,40160)

Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.

Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF

FRP MEMBRANE HOUSINGS W40E300

W40E300 FRP MEMBRANE HOUSINGS

Key Features:

Operating Temp Range: -10°C ---49°C

Internal permeate port not to exceed 125PSI(0.88 MPa)

Operating pH Range: 3 - 11

Cleaning pH Range: 2 - 12 (less than 30 minutes)

Mirror inner wall and brightly surface.

BSPP/NPT thread available

White color is as standard. Customized colors are also available.


Quality Assurance

Hydro-static Leakage Test Pressure:

Standard:

100% test, not sampling

— 100,000 times cyclic fatigue test

— Burst test with 6 times of its operating pressure

— 100% QA test with 1.1x design hydraulic pressure.

ASME: 1.1x Design Pressure

— 100% QA inspection and cleaning before final

packaging and delivery to customers.

— Submitted for NSF standard 61


Notice:

Please operate in accordance with User Guide!

All information is subject to change without prior notice. Please contact us for the latest product information and specifications.